TC-1U40 (400W)

TC-1U40 (400W)
model:TC-1U40

TC-1U40 (400W)

Safety Approval
Standard 1U dimension
Two 40mm Fans
Meet CE Rohs 2.0 2011/65/EU

1.Watts:400W


2.Input:
VOLTAGE: 90~135VAC or 185~260VAC (115/230 AUTO SELECTABLE)
FREQUENCY: 50/60Hz.
INPUT CURRENT: 8A for 115V AC, 4A for 230VAC.
INRUSH CURRENT: 60A for 115VAC, 80A for 230VAC


3.Output:

DOWNLOAD PDF

 Voltage:
+5V DC
+12V DC
-5V DC
-12V DC
+3.3V DC
+5VSB
 Maximum Load:
40A
20A
0.3A
0.8A
20A
2A
 Minimum Load:
3A
2A
0.1A
0.1A
0.3A
0.1A
 Ripple/Noise Max.(P-P):
50mv
120mv
150mv
150mv
50mv
50mv
 Line Regulation:
±1﹪
±1﹪
±1﹪
±1﹪
±1﹪
±1﹪
 Load Regulation:
±5﹪
±5﹪
±10﹪
±10﹪
±5﹪
±5﹪


◎  FEATURES:
* Meet CE RoHS 2.0 2011/65/EU.

* Auto Select AC input.
* Efficiency: ≧ 70﹪at full load.(Nominal Line)
* Hold-Up Time: 16ms at maximum load & normal input voltage.
* OVER VOLTAGE PROTECTION.
* SHORT CIRCUIT PROTECTION.
* OVER POWER PROTECTION.
* NO LOAD OPERATION.
* ENVIRONMENT TEMPERATURE
    Operation Temperature: 0℃ to 40℃
    Cooling: By forced air
    Storage Temperature:-20℃ to 70℃
    Humidity: 5 to 90﹪non-condensing.
* RELIABILITY
    MTBF OF POWER SUPPLY ELECTRONIS
    100,000 hours at full load and 25℃ ambient temperature
    LIFE EXPECTANCY OF FAN
    40,000 hours at 40℃


4.Dimensions:

L x W x H:  200 x  100  x 40.5 (mm)  /  7.87 x 3.94 x 1.59 (inches)

DOWNLOAD PDF


5.DownLoad:

UL TUV CB CE FCC

 


6.Connectors:


7.Others Certificates:

RoHS 2.0


8.Packing:

8pcs in One carton N.W. G.W. Carton Size
TC - 1U40 15.20 kgs 16.40 kgs 48 x 40 x 19cm
33.51 1bs 36.15 1bs 18.89 x 15.74 x 7.48 inch