500W+500W Redundant PSU for 2U
OPERATION TEMPERATURE: 0°C~50°CFile download
ALTITUDE DURING OPERATION:
UP TO 5000M
Outline: W76xH84xD180mm
OPERATION TEMPERATURE: 0°C~50°CFile download
ALTITUDE DURING OPERATION:
UP TO 5000M
Outline: W76xH84xD180mm
INPUT SPEC.
★Input voltage: 100 - 240Vac Full Range.
★Frequency: 50 - 60 Hz.
★Input Current: 6.5A for 115VAC, 3.5A for 230VAC.
★Inrush Current: 30A for 115VAC, 60A for 230VAC.
★Efficiency: The power efficiency shall meet 80plus Platinum.
★The minimum power factor shall be 0.9 with 50% load and input 230Vac/50Hz.
OUTPUT WATTAGE
500W
DC OUTPUT CHARACTERISTIC
| Output Voltage | Min. Current | Max. Current | Regulation | Ripple & Noise |
| +3.3V | 1A | 25A | ±5% | 50mV |
| +5V | 1A | 25A | ±5% | 50mV |
| +12V | 1A | 41A | ±5% | 120mV |
| -12V | 0A | 0.5A | ±5% | 120mV |
| +5VSB | 0.1A | 3A | ±5% | 50mV |
♦The combined total power from +3.3V and +5V shall not exceed 120W.
♦The max total power shall not exceed 500W.
FEATURES
★Temperature Range: Operating 0℃ to +50℃, Storage –20℃ to +70℃
★Hold up time: The output voltages stay in regulation at least 18ms with 75% load after loss of AC input.
★Over Current Protection
★Over Voltage Protection
★Short Circuit Protection
★Over Temperature Protection
★Altitude during operation: Up to 5000m
DIMENSION
L x W x H: 180 x 76 x 84 (mm) / 7.08 x 2.99 x 3.31 (inches)